Paloma Gas Heater
paloma controlpanels 3
Paloma Gas Heater

Gas Heater

Paloma gas heaters were initially distributed in Singapore by Hong Leong following their acquisition of Rheem Far East in 1985. In 1988, Paloma acquired Rheem, and Rheem Manufacturing Company (Singapore) Pte Ltd continued to distribute Paloma heaters independently of Hong Leong until around 2010. Since then, the technical and logistics teams for Paloma in Singapore have been disbanded, and there is no longer an official distributor for Paloma products in the region.

However, with extensive experience in servicing Paloma gas heaters, Homeone is the most capable vendor in Singapore for the repair and replacement of these units.

More about Paloma

Compatibility

Error Codes

Compliance and Safety

Deployment

compatibility icon new

Compatibility

Paloma Logo

Your Paloma gas heater offers unmatched compatibility, allowing for easy replacement with any gas or electric heater brand. Enjoy the freedom to choose the best water heating solution for your home.

For Rinnai, you can choose from the top-of-the-line Rinnai REU-2008W-RS or the more affordable REU-2024WP-RS.

The Macro MA-20WOD offers exceptional value, featuring built-in Wi-Fi for mobile app control.

For European brands such as Ferroli, the GS 20 OE TG(I) is highly competitive in pricing, with a new Wi-Fi model launched in 2024.

For conversion to an electric storage heater, selecting the right capacity from brands such as Rheem, Ariston, or Joven will provide an experience similar to that of a hotel.

Error Codes

The most common issues include C2 – 11: No ignition, typically caused by insufficient gas supply or a faulty PCB; Code A1 – 61: Fan blower motor failure or a faulty PCB; and Code E1 – 51: Gas inlet solenoid valve fault or a faulty PCB.

Currently the Printed Circuit Board (PCB) for MC-95 and MC-117 are both discontinued and will not be available in the future. Additionally, carbon monoxide emissions from incomplete combustion pose irreparable risks. If you suspect a gas leak, please contact us for a test.

Paloma Gas Heater Error Code A1 - 61
Paloma Error Code E1 - 51
safety shield

Compliance and Safety

EMA Licensed Gas Service Worker

All gas work in Singapore must be tested and signed off by an EMA Licensed Gas Service Worker before handing to a consumer with a certificate. The metal pipes to the heater requires equipotential bonding as required by EMA and plumber works to the heater to carried out or supervised by a PUB Licensed Plumber. All gas heater works by Homeone will comply with authorities such as EMA Gas, PUB and EMA Electric.

EMA Gas Service Worker Licence

Testing and certification of Gas work

EMA Electrician’s Licence

Electrical Compliance

PUB Plumber’s Licence

PUB pipe work compliance

Deployment

Same-day urgent call-outs are available. Site assessments with tests cost $50. Gas heater replacements, including U-gauge testing with EMA LGSW certification (according to Gas Supply Regulations 21), ensure for safe use in 4 hours. Despite fast response in attendance, the gas heater replacement work will also include:

1

For plumbing works, replacing sections of hot, cold, and recirculating pipes (where applicable) with stainless steel fittings and new stop valve for enhanced durability, especially for outdoor installations. Recycling old fittings has proven ineffective, as repeated untightening and tightening can cause material fatigue, leading to ruptures in the long run.

2

For gas work, replacing key gas pipe fittings, such as the gas valve and removal of union, which are the two most common components prone to gas leaks after heater replacement due to ageing. A section of the gas pipe either made of galvanised iron (GI) or copper will be replaced due to possibility of it being weakened after repeatedly tightening and dismantling. The copper pipe specifications will have to be Type Y or table Y complying with BS EN 1057.

copper tube


3

This work must be carried out or supervised by a fully Licensed Gas Service Worker (LGSW) from the EMA, not by someone with only a Restricted Licence. Testing of hot water at the fittings to ensure all are functioning as designed.
emalogo transparent


4

Full 1 year warranty on hardware and labour.

1YearWarranty

Paloma Projects

Bishan Point - Paloma PH-16SX & PH-20SX gas heater replacement

Bishan Point

Completion Year: 2005
Total Units: 164
Floors: 32
Model: Paloma Gas Heater (PH-16SX & PH-20SX)
Piping Material: Copper
Safety: Railing

Blue Horizon - Paloma PH-16SX gas heater replacement

Blue Horizon

Completion Year: 2005
Total Units: 616
Floors: 24
Model: Plaoma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: No Railing

Botanique at Bartley - Paloma PH-16SX gas heater replacement

Botanique at Bartley

Completion Year: 2005
Total Units: 616
Floors: 24
Model: Plaoma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Casa Merah - Paloma PH-16SX gas heater replacement

Casa Merah

Completion Year: 2009
Total Units: 556
Floors: 12
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Casablanca - Paloma PH-16SX replacement

Casablanca

Completion Year: 2006
Total Units: 478
Floors: 17
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: No Railing

City Square Residences - Paloma PH-20SX gas heater replacement

City Square Residences

Completion Year: 2009
Total Units: 910
Floors: 30
Model: Paloma Gas Heater (PH-20SX)
Piping Material: PPR
Safety: Railing

ClementiWoods - Paloma PH-163EWH gas heater replacement

ClementiWoods Condo

Completion Year: 2010
Total Units: 240
Floors: 5
Model: Paloma Gas Heater (PH-163EWH)
Piping Material: Copper
Safety: Railing

D'Grove Villas- Paloma PH-161ME gas heater replacement

D'Grove Villas

Completion Year: 1992
Total Units: 45
Floors: NA
Model: Paloma Gas Heater (PH-161ME)
Piping Material: Copper
Safety: No Railing

DunmanView - Paloma PH-16CWQE gas heater replacement

Dunman View

Completion Year: 2004
Total Units: 148
Floors: 18
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: Copper
Safety: Railing

Eastwood Vill - Paloma PH-16CWQE (1) gas heater replacement

Eastwood Ville

Completion Year: 2004
Total Units: 148
Floors: 18
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: Copper
Safety: Railing

FaberCrest - Paloma PH-16CWQFS(1) gas heater replacement

Faber Crest

Completion Year: 2002
Total Units: 360
Floors: 4
Model: Paloma Gas Heater (PH-16CWQFS(1))
Piping Material: to update
Safety: to update

Gardenvista- Paloma PH-16SX gas heater replacement

Gardenvista

Completion Year: 2006
Total Units: 318
Floors: 9
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Gloucester Mansions - Paloma PH-16CWQE (1) gas heater replacement

Gloucester Mansions

Completion Year: 2000
Total Units: 61
Floors: 18
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: Railing

Grange Heights - Paloma PH-16SX gas heater replacement

Grange Hights

Completion Year: 1976
Total Units: 120
Floors: NA
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: to update

Grange Infinite - Paloma PH-163EWH gas heater replacement

Grange Infinite

Completion Year: 2011
Total Units: 68
Floors: 36
Model: Paloma Gas Heater (PH-163EWH)
Piping Material: to update
Safety: to update

Hillview Regency - Paloma PH-16SX

Hillview Regency

Completion Year: 2005
Total Units: 572
Floors: 25
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: No Railing

Hillvista - Paloma PH-16SX gas heater replacement

Hillvista

Completion Year: 2006
Total Units: 778
Floors: 17
Model: Paloma Gas Heater (PH-163EWH)
Piping Material: Copper
Safety: Railing

D'Grove Villas- Paloma PH-161ME gas heater replacement

Kovan Melody

Completion Year: 2006
Total Units: 778
Floors: 17
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

https://www.homeone.com.sg/water-heater-portfolio/service-type-gas-water-heater/portfolio-product-brand-paloma-gas-heater/condo-name-la-casa/

La Casa

Completion Year: 2008
Total Units: 444
Floors: 12
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: No Railing

Le Crescendo - Paloma PH-16SX

Le Crescendo

Completion Year: 2006
Total Units: 228
Floors: 18
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Martia Residence - Paloma PH-16SX gas heater replacement

Martia Residence

Completion Year: 2007
Total Units: 20
Floors: NA
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: No Railing 

Mera Springs - Paloma gas heater replacement

Mera Springs

Completion Year: 2008
Total Units: 129
Floors: 21
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing 

Modena - Paloma PH-16CWQE (1) gas heater replacement

Modena

Completion Year: 2002
Total Units: 230
Floors: 12
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: Railing 

New Court - Paloma PH-16CWQE (1) gas heater replacement

New Court

Completion Year: 2001
Total Units: 20
Floors: 11
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: to update
Safety: to update

Newton Suites - Paloma PH-16SX gas heater replacement

Newton Suites

Completion Year: 2007
Total Units: 118
Floors: NA
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Northwood - Paloma PH-16SX gas heater replacement

Northwood

Completion Year: 2010
Total Units: 140
Floors: NA
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

One Leicester - Paloma PH-16SX gas heater replacement

One Leicester

Completion Year: 2009
Total Units: 194
Floors: 18
Model: Paloma Gas Heater (PH-16SX)
Piping Material: PPR
Safety: Railing

One St Michael's - Paloma PH-16SX gas heater replacement

One St Michael's

Completion Year: 2010
Total Units: 131
Floors: 25
Model: Paloma Gas Heater (PH-16SX)
Piping Material: PPR
Safety: Railing

Oxford Suites - Paloma PH-16SX gas heater replacement

Oxford Suites

Completion Year: 2011
Total Units: 60
Floors: 11
Model: Paloma Gas Heater (PH-16SX)
Piping Material: PPR
Safety: Railing

Parbury Hill Condominium - Paloma PH-161HS gas heater replacement

Parbury Hill Condominium

Completion Year: 1998
Total Units: 182
Floors: 5
Model: Paloma Gas Heater (PH-161HS & PH-20SX)
Piping Material: to update
Safety: No Railing

Parc Mondrian - Paloma PH-16SX gas heater replacement

Parc Mondrian

Completion Year: 2010
Total Units: 100
Floors: 16
Model: Paloma Gas Heater (PH-16SX)
Piping Material: PPR 
Safety: Railing

Park Green - Paloma PH-16CWQE gas heater replacement

Park Green

Completion Year: 2005
Total Units: 368
Floors: NA
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: Copper
Safety: to update

Pavilion 11 - Paloma PH-163EWH gas heater replacement

Pavilion 11

Completion Year: 2010
Total Units: 180
Floors: 31
Model: Paloma Gas Heater (PH-163EWH)
Piping Material: Copper
Safety: Railing

Regent Grove - Paloma PH-16SX gas heater replacement

Regent Grove

Completion Year: 2000
Total Units: 553
Floors: 16
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: to update
Safety: to update 

Riviera Residences - Paloma PH-16SX gas heater replacement

Riviera Residences

Completion Year: 2007
Total Units: 138
Floors: 10
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Riveria Gardens - Paloma PH-203EWH gas heater

Riveria Gardens

Completion Year: 2010
Total Units: 49
Floors: NA
Model: Paloma Gas Heater (PH-203EWH)
Piping Material: Copper
Safety: Railing

Sarkies Mansion - Paloma PH-16CWQE gas heater replacement

Sarkies Mansion

Completion Year: 1997
Total Units: NA
Floors: NA
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: to update
Safety: to update

Sam Kiang Mansions - Paloma PH-16CWQE gas heater replacement

Sam Kiang Mansions

Completion Year: 1999
Total Units: 59
Floors: 20
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: Copper
Safety: Railing

Savannah Condopark - Paloma PH-20SX gas heater replacement

Savannah Condopark

Completion Year: 2004
Total Units: 648
Floors: 8
Model: Paloma Gas Heater (PH-16SX & PH-20SX)
Piping Material: Copper
Safety: Railing

Sunshine Lodge - Paloma PH-16CWQE gas heater replacement

Sunshine Lodge

Completion Year: 1998
Total Units: 30
Floors: 4
Model: Paloma Gas Heater (PH-16CWQE)
Piping Material: to update
Safety: to update

Sunshine Plaza - Paloma PH-16CWQE (1) gas heater replacement

Sunshine Plaza

Completion Year: 2001
Total Units: NA
Floors: NA
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: No Railing

The Ansley - Paloma PH-16CWQE gas heater replacement

The Ansley

Completion Year: 2004
Total Units: 100
Floors: 25
Model: Paloma Gas Heater ( PH-16CWQE)
Piping Material: Copper
Safety: Railing

The Asteria - Paloma PH-16SX gas heater replacement

The Asteria

Completion Year: 2008
Total Units: 23
Floors: 5
Model: Paloma Gas Heater ( PH-16SX)
Piping Material: Copper
Safety: Railing

The Calrose - Paloma PH-16SX gas heater replacement

The Calrose

Completion Year: 2008
Total Units: 421
Floors: 5
Model: Paloma Gas Heater (PH-16CWQE & PH-16SX)
Piping Material: PPR
Safety: Railing

The Esparis - Paloma PH-16SX gas heater replacement

The Esparis

Completion Year: 2008
Total Units: 421
Floors: 5
Model: Paloma Gas Heater (PH-16CWQE & PH-16SX)
Piping Material: Copper
Safety: No Railing

The Esta - Paloma PH-16SX gas heater replacement

The Esta

Completion Year: 2008
Total Units: 400
Floors: 21
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

The Florida - Paloma PH-16CWQE & PH-16SX gas heater replacement

The Florida

Completion Year: 2000
Total Units: 496
Floors: 16
Model: Paloma Gas Heater (PH-16CWQE & PH-16SX)
Piping Material: Copper
Safety: No Railing

The Gardens at Bishan - Paloma PH-16CWQE (1) gas heater replacement

The Gardens at Bishan

Completion Year: 2004
Total Units: 756
Floors: 20
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: No Railing

The Lakeshore - Paloma PH-16SX gas heater replacement

The Lakeshore

Completion Year: 2007
Total Units: 848
Floors: 17
Model: Paloma Gas Heater ( PH-16SX)
Piping Material: PPR
Safety: Railing

The Light @ Cairnhill - Paloma PH-16CWQE (1) gas heater replacement

The Light@Cairnhill

Completion Year: 2004
Total Units: 118
Floors: 20
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: Railing

The Marbella - Paloma PH-16SX gas heater replacement

The Marbella

Completion Year: 2005
Total Units: 239
Floors: 24
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

The Nclave - Paloma PH-16SX gas heater replacement

The Nclave

Completion Year: 2008
Total Units: 30
Floors: 5
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

The Quartz - Paloma PH-16SX gas heater replacement

The Quartz

Completion Year: 2010
Total Units: 625
Floors: 10
Model: Paloma Gas Heater (PH-16SX)
Piping Material: PPR
Safety: Railing

The Sea View - Paloma PH-16SX water heater replacement

The Sea View

Completion Year: 2008
Total Units: 546
Floors: 22
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

The Woodgrove - Paloma PH-16CWQE (1) gas heater replacement

The Woodgrove

Completion Year: 1998
Total Units: 72
Floors: NA
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: No Railing

Viz at Holland - Paloma PH-20SX gas heater replacement

Viz at Holland

Completion Year: 2008
Total Units: 165
Floors: 14
Model: Paloma Gas Heater (PH-20SX)
Piping Material: Copper
Safety: Railing

Whitewater- Paloma PH-16SX gas heater replacement

Whitewater

Completion Year: 2005
Total Units: 397
Floors: NA
Model: Paloma Gas Heater (PH-16SX)
Piping Material: Copper
Safety: Railing

Yew Mei Green - Paloma PH-16CWQE (1) gas heater replacement

Yew Mei Green

Completion Year: 2000
Total Units: 712
Floors: 22
Model: Paloma Gas Heater (PH-16CWQE (1))
Piping Material: Copper
Safety: Railing

Gas Heater Remote Controls

Paloma Gas Heater WALLMAN CUTE16 with MC 95

Paloma Gas Heater WALLMAN CUTE16 with MC-95

PH-16CWQE Specifications:

Outdoor Use 148800 BTU/H Year 1997
Made by Paloma Industries Ltd in Japan

PH 16SX WITH MC 117 remotecontrol

Paloma Gas Heater PH-16SX WITH MC-117

PH-16SX Specifications:

Outdoor Use 119100 BTU/H Year 2008

Made by Paloma Industries Ltd in Japan

What to do when you see an error code?

Paloma Gas Heater 7

Call a certified professional NOT a handyman

Handyman does not have the training to handle a gas heater. Get a BCA registered contractor or a Licensed Gas Worker

warning icon

DO NOT allow modification to the heater. It is dangerous!

The most dangerous modifications are bypassing the safety controls

  • To bypass the thermocouple and
  • Removal of the solenoid valve and replace with an empty pipe so that the heater doesn’t shut down when it detects a gas leak.

The most serious being bypassing the solenoid valve. This is removing the safety valve that will shut off the whole system when it detects a gas leak.

Refer to the table below to ascertain the issue.

Gas Heater Error Codes Guideline

CodeFaultPoint to Check
03EZ LinkCheck communications cable. Ensure dip switch 4 on DIP1 set of switches is in the ON position on both heaters.
05Imperfect Combustion AlarmClean air inlet filter. Clean combustion air fan. Clean heat exchanger fins. Check for adequate combustion air ventilation openings and clean if necessary. Check vent system for partial blockage and correct as necessary.
10

Air Supply or Exhaust Blockage

Warning code not a fault code.

Check all vent components for proper connections. Ensure there are no restrictions in the flue inlet or exhaust. Ensure condensation trap/drain was installed correctly. Ensure heat exchanger fins, fan, and air intake are not blocked.
11No IgnitionEnsure gas supply to the appliance is turned ON. Ensure gas type and pressure is correct. Bleed all air from gas lines. Ensure gas line, meter, and regulator are sized properly. Ensure appliance is properly grounded. Check gas solenoid valves for open or short circuits. Ensure igniter is operational. Check igniter wiring for damage. Check heat exchange thermistor and transformer.
12Flame Failure

Ensure gas type and pressure is correct. Bleed all air from gas lines. Ensure flame rod wiring is correct. Check flame rod for carbon build-up. Ensure gas line, meter, and regulator are sized properly.

Ensure appliance is properly grounded. Check gas solenoid valves for open or short circuits. Check power supply for proper voltage and voltage drops. Disconnect remote control. Check heat exchange thermistor and transformer.

14Overheat Limiter Fault

Ensure high fire and low fire gas burner pressure is correct. Check gas type of unit and ensure it matches gas type being used. Check heat exchanger for cracks and/or separations. Check gas type connector. Check for restrictions in airflow around unit and vent terminal. Check over heat limiter wiring and ensure it is plugged in correctly.

15Boiling Safety Device

Check for closed water heater inlet valve or restrictions in cold water inlet pipe (must be fully open). Check for clogged heat exchanger (scale build up). On a commercial water heater, lower the set point temperature below 82°C at high altitude. Check heat exchange and hot water outlet thermistor.

16Over Temperature Warning

Check for blocked heat exchanger. Check for restrictions in airflow around unit and vent terminal. Check PGFR, heat exchanger thermistor and hot water outlet thermistor.

24Malfunction of Operational Switch

Disconnect remote control and retry. Verify unit is electrically grounded. Ensure Min, Max and/or Adjuster buttons have not been inadvertently depressed.

29Heat Exchanger Outlet Temp. Too LowCheck air intake filters and heat exchanger fins.
31Water Inlet Temperature Sensor FaultCheck sensor wiring is intact and not damaged. Check and clean scale from sensor if necessary. Ensure resistance is correct.
32Heat Exchanger Temperature Sensor Fault
33Outgoing Water Temperature Sensor Fault
34Ambient Air Temperature Sensor Fault
35Improper Thermistor ConnectionCheck that all thermistors are connected to proper connections on PCB. Ensure the hot and cold plumbing to the heater is not reversed.
 
 
 
CodeFaultRemedy

51

Gas Inlet Solenoid Valve FaultCheck gas inlet solenoid valve wiring for loose or damaged terminals. Check flame rod.
52PGFR Valve FaultCheck PGFR valve wiring for loose or damaged terminals.

61

Combustion Fan Failure

Ensure fan motor will turn freely. Motor will operate with a small amount of restriction. Check wiring to motor for damaged and/or loose connections. Ensure the flue length does not exceed max length and number of bends. Check transformer and PCB.

65

Water Volume Control Fault

Check water flow solenoid valve wiring harness for loose or damaged terminals. Check for proper voltage to water flow solenoid.

66

Water By-Pass Control Fault

Check water by-pass solenoid valve wiring harness for loose or damaged terminals. Check for proper voltage to water by-pass solenoid.
71Gas Inlet Solenoid Valve Control FaultCheck gas inlet solenoid valve wiring for loose or damaged terminals. Ohm out solenoid valve.

72

Flame Sensing Device Fault

Ensure flame rod is touching flame when unit fires. Check inside burner chamber for any foreign material blocking flame at flame rod. Check all wiring to flame rod for damage. Check flame rod for proper voltage. Remove flame rod and check, clean with steel wool.

76

Communication Fault with Remote Control

Check remote control wiring for loose or damaged connections. Bypass remote control cable by connecting remote control directly to remote control terminals on PCB. Replace cable if found to be faulty.

79

Fan Motor Current Fault

Ensure fan motor will turn freely. Motor will operate with a small amount of restriction. Check fan motor for proper voltage and for water (condensation) damage.

80Gas Cut-off FailureOhm out all solenoid valves. Check voltage of all flame rods.
82PCB data failure. Control board is not programmed.Ensure gas type connector is fitted.
90Blocked Flue FaultClean any blockage in heat exchanger, combustion fan, inlet filter, and exhaust flue.
99Fan Motor cannot ventClean Air Inlet Screen; Clear vent blockages Check for blocked heat exchanger.

No code

Nothing happens when water is flowing through unit.