6 Jun 2024

Mitsubishi Aircon System 1: BCA Trained Aircon Installation for HDB at 429A Bedok North Road on 5 Jun 2024

an HDB unit at 429A Bedok North Road without Aircon Ledge.
The aircon installation has been approved by HDB HQ engineer and required to engage BCA trained Installer carried out installation, ensuring safety and compliance with BCA, HDB & EMA regulations

  • Project location

    HDB at 429A Bedok North Road

  • Property type

    HDB

Mitsubishi Aircon System 1: BCA Trained Installation for HDB at 429A Bedok North Road on 5 Jun 2024

Before

After

Mitsubishi Aircon System 1 BCA Trained Aircon Installation

Job Scope

Mitsubishi Aircon System 1 Supply

  1. Outdoor Unit MUYGP10VF
  2. Indoor Unit MSYGP10VF, Master Room, 9,000 BTU
  3. Gas Type R32
  4. Efficiency 5 TICKS

BCA Trained Aircon Installation

  1. Filing BCA Form AC-02 to HDB, ensuring safety and comply with BAC, HDB and EMA Regulation for the installation.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installation. BCA Form AC 02 filling to HDB
  2. Installing a SS304 Bracket with Rubber padding, preventing the bracket rusty and cause the aircon drop and anti white noise.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installer. SS304 Stainless Steel Bracket
  3. Laying 4 Core Wire for 15 meters from indoor unit to outdoor unit. Live, Neutral, Earth, Communication.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installer. 4 core wires (Live, neutral, earth, communication)
  4. Laying Copper pipe for 15 meters of TUV/PSB Singapore Certified.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installation. Copper Pipe
  5. Laying 15 meters of 16mm PVC Drainage pipe.
  6. Laying 15 meters of trunking to enclose all the copper and drainage pipe and 4 core wire.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installation. Trunking
  7. Applying insulation gum for copper and darinage pipes to prevent condensation water and extend lifespan.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installer. Apply gum for Insulation
  8. Installing a Mitsubishi System 1 aircon.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installation. Mitsubishi System 1 indoor unit FCU
  9. Vacuuming 20 munites to optimizing efficiency with quality assurance to eliminate unwanted air and moisture from the refrigerant system.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installer. Vacuum 20 minutes

EMA Licensed Electrical Work

  1. Filling Form CS/5H to HDB for Electrical Work Submission.
  2. Installing a 20A MCB for the Mitsubishi Aircon system 1 aircon electric supply.
    Mitsubishi Aircon System 1: BCA Trained Aircon Installer. 20A MCB Installation
  3. Installing 15 meters of 2.5mm2 Wires for the Mitsubishi Aircon system 1 electric supply.
  4. Installing a 20A Isolator for the Mitsubishi Aircon system 1 electric supply and maintenance.

Testing and Commission

  1. Super Heat Analysis
  2. Heat Transfer Analysis – Mitsubishi Aircon system 1 provide 10°C of the heater transfer from indoor to outdoor.
    Inlet Temperature: 25°C
    Off Coil Temperature: 15°C
    Heat Transfer 10°C

    Mitsubishi Aircon System 1: BCA Trained Aircon Installer. Super Heat Analysis, Heat Transfer Analysis.

After Sales Service

  1. Homeone provides a one-year engineering warranty for Mitsubishi Aircon System 1
  2. Manufacturer warranty for Mitsubishi Aircon System 1

 

 

HDB Aircon Installation Regulation

Air-Conditioners

  • Regular maintenance of your air-conditioner will help prolong its lifespan and keep it running efficiently. It is also important to check the brackets holding up the air-conditioner condenser as any loose bolts or improper installation can result in accidents.

Maintenance tips

  • Have your air-conditioner serviced regularly by a licenced service provider. Ask the service provider whether your condenser unit requires a replacement of brackets due to rust and corrosion.
  • In addition, clean the air-filters of your air-conditioners to maintain optimal airflow.

Penalties

  • Under the Building Control Act, homeowners can face a penalty of up to S$5,000 and/ or jail term of up to six months for improper installation of air conditioner.
  • In addition, flat owners can also face a fine of up to $10,000 and/ or a jail term of up to one year, if the air-conditioner falls due to lack of maintenance, under the Building Maintenance and Strata Management Act (BMSMA).

Building and Construction Authority (BCA) list of approved air-conditioner installers

 

 

BCA Trained Installer for Installation of Air-conditioning Unit

Trained Installer for Installation of Air-conditioning Unit

  • A trained air-conditioning unit installer is an individual certified by the Building and Construction Authority to carry out air-conditioning unit installation works.
  • As per Regulation 41B (2) of the Building Control Regulations 2003, only a trained air-conditioning unit installer can install any air-conditioning unit on the exterior of any building or which projects outwards from any building.

Installation requirements and duties of the trained air-conditioning unit installer

As per Regulation 41C of the Building Control Regulations 2003, the trained air-conditioning unit installer must:

Failure to do so may result in a penalty of up to $5,000 or jail term of up to six months or to both.

Trained air-conditioning unit installer

  • To check for Trained Air-conditioning Unit Installers, please submit your enquiry via our our Feedback Form.
  • Please select “Category: BCA Academy Course”, followed by “Sub Category: BCA Academy Courses” and submit the installer’s name and Pass Number.

 

Electrical Loading of Your HDB Block

  • HDB apartment blocks completed on or after 1 Jan 1994 are provided with a 40 amps main switch. Incoming electrical supply is also upgraded for blocks under the Main Upgrading Programme (MUP). Flat owners need not apply for an HDB permit to install an air-conditioner or other higher capacity equipment/appliances if the flat is provided with higher electrical loading.
  • To check if your flat is provided with higher electrical loading, please enter the postal code for your HDB block:

Got A Question?